Price:
CALL FOR PRICE -
Location:
Winnipeg, Manitoba - (800) 437-2924
Interested in this machine? Send us a message
PriceWatch
Subscribe to be notified of price changes on this item.
2021 Other Generator & Power Unit ATC480500K
Fields with asterisks * are required.
Print This Page
Description
AUTO TUNE PFC UNIT
Inventory ID
U00005736
Serial
A2149003
Machine Location
Details
- Inventory ID: U00005736
- Status: On Yard
- Make: Other
- Year: 2021
- Model: ATC480500K
- Serial#: A2149003
- Est Hours: 0
Notes
- PGS-500 POWER CONDITIONER EQUIPPED PER THE BELOW:
- - 500KVAR 9 STEPS OF 50KVAR/ 2 STEPS OF 25KVAR 480V
- ON-BOARD MAIN CIRCUIT BREAKER
- TX2 - MULTI-TAP SPLIT CORE CURRENT TRANSFORMER
- APPLICATION FOR SERVICE ENTRANCE POWER FACTORCORRECTION INSTALLATION
REQUIRING PRECISE MAINTENANCE OF TARGET POWER FACTOR
- CABINET IS 12 GAUGE STEEL WITH ANSI 61 GREY POWDER FINISH LIFT BOLTS
STANDARD NEMA 1
- POWER LINE INTERCONNECT: RUGGED COPPER BUS BAR CONNECTION WITH ACCESS
PROVIDED FOR TOP OR BOTTOM ENTRY. BUS BARS ARE BRACED FOR 65KAIC AT 600V. ALL
INTERNAL POWER WIRING CONNECTIONS FROM BUS ARE LAID OUT ON A MOST DIRECT BASIS
WITH MINIMUM BENDS
FOR EASE OF TROUBLESHOOTING
- MODULARTRAY DESIGN: CAPACITOR BANKS ARRANGED IN MODULAR TRAYS WITH
CAPACITORS FUSES
- BLOWN FUSE INDICATING LIGHTS AND CONTACTORS GROUPED IN A LOGICAL EASILY
UNDERSTOOD LAYOUT.
- FUSING: UL RECOGNIZED 200 000A INTERRUPTING CAPACITY PROVIDED ON ALL THREE
PHASES OF EACH BANK. BLADE-TYPE FUSES MOUNTED ON INSULATOR STAND-OFFS.
- BLOWN FUSE INDICATOR LIGHTS
- PUSH TO TEST
- AUTO LOCATE: WHEN DOOR IS OPEN AND BUS ENERGIZED FUSE CIRCUIT AUTOMATICALLY
CHECKS FOR CLEARED FUSES.
- DOOR INTERLOCK: AUTOMATICALLY TURNS OFF CONTROL CIRCUIT WHEN ENGAGED. POWER
CONTINUES TO BE PROVIDED TO THE UNIT UNTIL DISCONNECT IS OPEN.
- EXHAUST FAN: TWO FANS PER CABINET PROVIDE THERMAL PROTECTION. DUST FILTERING
PROVIDED.
- EASE OF EXPANSION: CAPACITOR STAGE NESTS ARE SELF-CONTAINED AND CAN BE ADDED
IN THE FIELD
- EASE OF REPLACEMENT: CELLS CAN BE EASILY INDIVIDUALLY REPLACED BY REMOVING THE
MOUNTING BOLT AND LIFTING OUT OF THE NEXT WITHOUT REMOVAL OF ANY OTHER
COMPONENTS
- CONTROLLER FEATURES: DIGITAL DISPLAY OF POWER FACTOR & NUMBER OF ENERGIZED
BANKS VISUAL INDICATION OF INSUFFICIENT KVAR TO REACH TARGET POWER FACTOR
CAPACITORS DISABLED IN STEPSWITHIN 35 MSEC OF MAIN POWER INTERRUPTION
AUTOMATIC DETECTION AND CORRECTION OF CT AND PHASE POLARITY PROVIDED
PROTECTION AGAINST OVERVOLTAGE OVERTEMPERATURE AND HARMONIC OVERLOAD EVENTS
- CONTACTOR FULLY RATED FOR CAPACITOR SWITCHING UP TO 60KVAR AT 600V
- CONTACTOR INTEGRAL PRE-CHARGE/PRE-INSERTION MODULE STANDARD
- FIVE-YEAR WARRANTY OF COMPONENTS.